Guangzhou UC Instruments., Co. Ltd.

Guangzhou UC Instruments., Co. Ltd.

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Optical Oscilloscope /

Full Rate 10Gbps Clock Recovery Module For Optical Network Equipment

Contact Now
Guangzhou UC Instruments., Co. Ltd.
Visit Website
City:guangzhou
Country/Region:china
Contact Person:MrJack Zhou
Contact Now

Full Rate 10Gbps Clock Recovery Module For Optical Network Equipment

Ask Latest Price
Video Channel
Brand Name :YOUCii
Model Number :U9710B
Place of Origin :CHINA
MOQ :1pcs
Price :negotiate a price
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :5 pcs+per month
Delivery Time :20 work days
Packaging Details :Carton
Certification :CU,IOS
Product name :10Gbps Clock Recovery Module
Application :Optical Network Equipment
Model :U9710B
Wavelength range :800nm
Data rate :10Gbps
Custom :available
more
Contact Now

Add to Cart

Find Similar Videos
4/8 Channel Optically Controlled Optical Attenuator Multiple Devices Can Be Cascaded 02:10
4/8 Channel Optically Controlled Optical Attenuator Multiple Devices Can Be Cascaded
View Product Description

U9710B Full Rate 10Gbps CDR

No. Specifications Max. Min. Unit.
1 Data rate range 11.3 0.155 Gbps
2 Wavelength range 1600 800 nm
3 Optical input range (determined by module sensitivity) +3 -15 dBm
4 Output recovered electrical clock range 5.65 / 2.825 0.0775/0.03875 GHz
5 Output electrical clock amplitude 600(typical value) mVpp
6 Clock rise time(OC-192)(20%~80%) 33.1 22.2 ps
7 Clock fall time(OC-192)(80%~20%) 33.7 23.9 ps
8 Output Jitter(10.3125Gbps) 1 (typical value) ps
9 Clock frequency(10.3125Gbpsrate, divided by2/4) 5.156 / 2.578 5.156 / 2.578 GHz
10 Internal Loss of Signal Detect (LOS) 128 (overload) 5 (sensitivity) mV
11 Power supply voltage (input voltage of external power supply) 5.5 4 V
12 Operating temperature 85 -40

U9710 CDR (Clock Recovery Module ) is mainly used to provide clock recovery signal in the test environment without triggering clock, so as to use the sampling oscilloscope to test the optical eye diagram of the device. The typical application is the testing of optical network equipment or the BOB product in PON application. Because the photometric device itself has no frequency division clock output, it is necessary to recover the clock signal to trigger the sampling oscilloscope when testing the optical eye diagram.
U9710 CDR has a SFP optical port, which is suitable for SFP encapsulated conventional SFP, SFP+, OLT SFP and other optical modules. It only needs the receiving end of the optical module to convert the optical signal to the electrical signal, and then extract and output the clock of the electrical signal. Clock signal is mainly used for the trigger signal of oscilloscope. This device self-adapts to the rate and does not require software configuration.

FAQ

Q: Are you a factory manufacturer?

A: Yes we are manufacturer with 13 years experience in this industry and supplied many good quality products.

Q: Where is your main market?

A: Asia, Europe, America, Middle-East, Africa and other countries and regions.

Q:What is your minimum order quantity (MOQ)?

A: As a standard policy, we accept MOQ of 1set, and mixed items available, it still needs to confirm with our sales according to different product lines.

Q: Can I customize the size and color of the case?

A: Yes. We can discuss it .

Q: Can I buy some samples first before main orders? Is the sample fee refundable?

A: Yes, sample fee and shipment fee should be paid in advance .

Q: How long is the Production Lead Time?

A: 5 days for stock products, different products have different delivery times, according to the actual situation.

Inquiry Cart 0
You May Like
Dual Channel Polarization Preserving Optical Attenuator  0~45DB
Dual Channel Polarization Preserving Optical Attenuator 0~45DB
USB Optical Oscilloscope Four Channel Multi Rate BERT Support 10Gbps 9.953/10.3125G
USB Optical Oscilloscope Four Channel Multi Rate BERT Support 10Gbps 9.953/10.3125G
Fast Speed Optical Oscilloscope 100G 400G BERT Bit - Error Tester Support 9.953-11.3G/25-28G
Fast Speed Optical Oscilloscope 100G 400G BERT Bit - Error Tester Support 9.953-11.3G/25-28G
10G Full Rate BERT Support 622M-15G An Electric One Mouthful Dual Channel
10G Full Rate BERT Support 622M-15G An Electric One Mouthful Dual Channel
100G/400G Bit Error Tester BERT 240V SMA Connector Type
100G/400G Bit Error Tester BERT 240V SMA Connector Type
10G Four Channel Bit Error Tester BERT Support 10Gbps Multiple Rates
10G Four Channel Bit Error Tester BERT Support 10Gbps Multiple Rates
Full Rate 10Gbps CDR Clock Recovery Module Adaptive Rate
Full Rate 10Gbps CDR Clock Recovery Module Adaptive Rate
10G Digital Communication Analyzer Low Speed DCA 1.2442/1.25G
10G Digital Communication Analyzer Low Speed DCA 1.2442/1.25G
10G Four Channel Bit Error Tester BERT Support 9.953Gbps 10.3125/10.519/10.702/11.096/11.317Gbps
10G Four Channel Bit Error Tester BERT Support 9.953Gbps 10.3125/10.519/10.702/11.096/11.317Gbps
10Gbps Full Rate 10Gbps CDR Clock Recovery Module 0.155~11.3G
10Gbps Full Rate 10Gbps CDR Clock Recovery Module 0.155~11.3G
32 Gbaud PAM4 CDR PON/BOB Test Support 25GBaud~32GBaud
32 Gbaud PAM4 CDR PON/BOB Test Support 25GBaud~32GBaud
Module Auto Test System OLT SFP SFP+/XFP ONU Speed 10G Or Less
Module Auto Test System OLT SFP SFP+/XFP ONU Speed 10G Or Less
10G Full Rate Data Error Transmission Tester Error Analysis And Detection Fault Tester BERT
10G Full Rate Data Error Transmission Tester Error Analysis And Detection Fault Tester BERT
100Gbps Multi - Frequency Division Clock Recovery Instrument
100Gbps Multi - Frequency Division Clock Recovery Instrument
10G Full Rate Single Mode / Multi - Mode Optical Oscilloscope
10G Full Rate Single Mode / Multi - Mode Optical Oscilloscope
Send your message to this supplier
*From:
*To:

Guangzhou UC Instruments., Co. Ltd.

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now