Guangzhou UC Instruments., Co. Ltd.

Guangzhou UC Instruments., Co. Ltd.

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Optical Oscilloscope /

56Gbaud PAM4 CDR Module Clock Recovery Instrument

Contact Now
Guangzhou UC Instruments., Co. Ltd.
Visit Website
City:guangzhou
Country/Region:china
Contact Person:Jack Zhou
Contact Now

56Gbaud PAM4 CDR Module Clock Recovery Instrument

Ask Latest Price
Video Channel
Brand Name :YOUCii
Model Number :U9740B
Place of Origin :CHINA
MOQ :1pcs
Price :negotiate a price
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :5 pcs+per month
Delivery Time :20 work days
Packaging Details :Carton
Certification :CU,IOS
Product name :PAM4 CDR Module
Data rate range :56Gbaud, 25-64Gbaud
Wavelength range :1250-1650nm
Clock Recovery Output Divider :2 / 4 / 8 / 16 / 32 / 64
Model :U9740B
OEM :available
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

U9740B 56Gbaud PAM4 CDR

No. Specifications Max. Min. Unit.
1 Data rate range 64 25 Gbps/Gbaud
2 Wavelength range(single mode) 1650 1250 nm
3 Optical input range +5 -15 dBm
4 Clock Recovery Output Divider 2 / 4 / 8 / 16 / 32 / 64
5 Output electrical clock amplitude 500(typical value) mVpp
6 CML clock differential output amplitude 800 200 mVpp
7 Clock output random jitter 500 300 fs
8 Clock frequency (take 28.1Gbps as an example) 14.05 0.44 GHz
9 Internal Loss of Signal Detect (LOS) 128 (overload) 5(sensitivity) mV
10 Power supply voltage (external power supply input voltage) 5.5 4 V
11 Operating temperature 70 10
12 Adaptable module types (support NRZ and PAM4 signals) SFP28/56, SR, LR, BIDI

U9740B CDR (clock recovery instrument) is mainly used to provide clock recovery signals in the test environment without triggering the clock, so as to use the sampling oscilloscope to test the optical eye diagram of the device. Typical application is the test of optical network equipment, or for BOB products in PON application, because the measured equipment itself does not have the output of the frequency division clock, the clock signal needs to be recovered to trigger the sampling oscilloscope when testing the optical eye map.

U9740B CDR with an FC optical interface adapter, suitable for conventional SFP28/56, SR, LR and BIDI module optical signal access, support NRZ and PAM4 signals, FC optical interface to receive optical signals into electrical signals, CDR will be the electrical signal clock extracted and output. Clock signal is mainly used in oscilloscope trigger signal.

FAQ
Q: Are your company a trading one or a factory?
A: We are a fcatory in Guangdong. Our company has a professional foreign trade sales team and an experienced technical support team. We are supplier for Light source, optical power meter, optical attenuator, optical switch and BERT, DCA, CDR.
Q: What is the price term?
A: FOB ShenZhen
Q: What’s the warranty time?
A: 12 months after shipment date.
Q: How to place order?
A: Talk to service staff, confirm machine details, and then place order.